| Flow Measurement | |
|---|---|
| Repeatability | +/- 0.15% of reading |
| Uncertainty* | +/- 0.5% of reading |
| Turndown ratio | 1000:1 |
| Operating flow range | +/- 0-4000 ml/min |
| Measurement flow range | 4-4000 ml/min |
| Measurement rate | 1.1 kHz |
| Maximum operating pressure | 20 barg (2000 kPag) |
| Pressure drop at maximum flow | < 20 kPa (4000 ml/min for pump petrol @ 20°C) |
| Fluid temperature range | -20°C to +120°C |
| Ambient temperature range | -40°C to +120°C |
| Temperature Measurement | 2 x 1000 Ohm RTD (1/3 DIN standard) |
| Mechanical | |
| Dry weight | 330 g |
| Fluid capacity | 15 ml |
| Wetted materials | FPM, anodised aluminium alloy, stainless steel |
| Fuel line connection | -6AN fittings 9/16-inch UNF thread |
| Deutsch sensor connector | ASDD006-09PC-HE |
| Deutsch mating connector | ASDD606-09SC-HE |
| Environmental | |
| Storage temperature | -40°C to 85°C |
| External pressure rating | 300 kPa |
| Environmental protection | IP69K (when mated to connector) |
| Electrical Supply | |
| Voltage | 8V to 30V DC |
| Current | < 70 mA @ +12V DC |
| Voltage protection | Over-voltage 45V DC, reverse polarity -45V DC |
| CAN Communications | |
| Design standard | ISO 11898-2 (high-speed applications) |
| Message format | 2.0A (11-bit identifier) |
| Baud rate | 1 Mbit/sec |
| CAN termination resistor | No |
| TTL Pulse Output | |
| Voltage output range | 0-5V |
| Pulses per cc | 3000 (fully configurable) |
| Duty cycle | 50% |
| Output resistance | 1.0 kOhm |
| Analog Output | |
| Voltage output range | 0-10V DC |
| Resolution | 16-bit |
| Output resistance | 47.0 Ohm |
| Load resistance | > 1.0 kOhm |
| Configuration Interface | 3.3V serial interface |
| Fuel Compatibility | Petrol, diesel, bio-diesel,ethanol, methanol please contact us about other fluids |
* Calculated according to ISO/TR using root-sum square method yielding 95% confidence
Specifications subject to change without prior notice